AMX NXB-CCG-K Informations techniques Page 73

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 144
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 72
73
Lutron® integration protocol
DEVICE Command-specific fields (continued)
Component Numbers (continued):
Component Component Number Available Actions
Shade Column 1 Open LED
1
174 Get (?) LED state
Shade Column 1 Preset 1 LED
1
175 Get (?) LED state
Shade Column 1 Close LED
1
211 Get (?) LED state
Shade Column 2 Open LED
1
183 Get (?) LED state
Shade Column 2 Preset 1 LED
1
184 Get (?) LED state
Shade Column 2 Close LED
1
220 Get (?) LED state
Shade Column 3 Open LED
1
192 Get (?) LED state
Shade Column 3 Preset 1 LED
1
193 Get (?) LED state
Shade Column 3 Close LED
1
229 Get (?) LED state
NOTE
1. Not supported in QS Standalone.
Action Numbers and Parameters:
Action Action Number Parameters
Press/Occupied 3 None
Release/Unoccupied 4 None
Set Current Scene
1,2
7 Scene
Set (#) or Get (?) LED State
3
9 0 = Off
1 = On
2 = Normal-Flash: 1 flash every second
2
3 = Rapid-Flash: 10 flashes every second
2
Scene Save 12 Scene
Get/Set Light Level
4,5
14 Level = 0 –100 or 0.00 –100.00
Fade
6
in: SS.ss
7
, SS, MM:SS, or HH:MM:SSJ79 (QS Standalone
fade: maximum 4 hours)
Delay
6
in: SS.ss
7
, SS, MM:SS, or HH:MM:SS (QS Standalone delay:
maximum 4 hours)
Set Zone Lock
8
15 0 = Off; 1 = On
Set Scene Lock
8
16 0 = Off; 1 = On
Set Sequence State
8
17 0 = Off
1 = Sequence through Scenes 1–4
2 = Sequence through Scenes 5–16
Start Raising
4,5
18 None
Start Lowering
4,5
19 None
Stop Raising / Lowering
4,5
20 None
Get/Set Timeclock State 34 0 = Disabled
1 = Enabled
NOTES
The number of zone controllers available matches the number of zones a particular model supports.
1. Not supported in HomeWorks® QS.
2. Not supported in RadioRA® 2.
3. Quantum® or HomeWorks® only. “Set” is for unprogrammed buttons and buttons with LED logic ‘Defined by Integration.’
4. Use OUTPUT command with equivalent command in RadioRA® 2.
5. Use OUTPUT command with equivalent command in HomeWorks® QS.
6. The Fade and Delay time are optional. When not used, the system will use a one-second fade time with zero-second delay.
7. Fractional seconds “SS.ss” will be rounded down to the nearest quarter second. For example, if a fade time is specified
as 1.31 seconds a value of 1.25 seconds will be used.
8. QS Standalone only.
GRAFIK Eye® QS (continued)
DEVICE Commands (continued)
1 2 3 4 5 6
Scene 1
OK
Fade Time
03 Seconds
Vue de la page 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 143 144