119
Lutron® integration protocol
Sivoia® QS Venetian Blind (continued)
OUTPUT Commands
OUTPUT Command Format
OUTPUT Command-specific fields
Action Numbers and Parameters:
Action Action Number Parameters
Set (#) or Get (?)
Venetian lift level only
1 Lift Level
1
= 0 –100 or 0.00 –100.00
Fade
2
in: SS.ss
3
, SS, MM:SS, or HH:MM:SS
Delay
4
in: SS.ss
3
, SS, MM:SS, or HH:MM:SS
Set (#) or Get (?)
Venetian tilt level only
9 Tilt Level
1
= 0 –100 or 0.00 –100.00
Fade
2
in: SS.ss
3
, SS, MM:SS, or HH:MM:SS
Delay
4
in: SS.ss
3
, SS, MM:SS, or HH:MM:SS
Set (#) or Get (?)
Venetian lift & tilt level
10 Lift Level
1
= 0 –100 or 0.00 –100.00
Tilt Level
1
= 0 –100 or 0.00 –100.00
Fade
2
in: SS.ss
3
, SS, MM:SS, or HH:MM:SS
Delay
4
in: SS.ss
3
, SS, MM:SS, or HH:MM:SS
Start raising Venetian tilt 11 None
Start lowering Venetian tilt 12 None
Stop Venetian tilt 13 None
Start raising Venetian lift 14 None
Start lowering Venetian lift 15 None
Stop Venetian lift
16 None
NOTES
1.
2.
Fade is not available for blinds since they move at a constant rate. The parameter must be entered but is ignored.
3. Fractional seconds “SS.ss” will be rounded down to the nearest quarter second. For example, if a delay time is specified
as 1.45 seconds, a value of 1.25 seconds will be used.
4. The Delay time is optional. When not used, the system will use a zero-second delay. The minimum delay time is
0.25seconds. The maximum delay time is 4 hours. Not supported in QS Standalone.
Use “OUTPUT Command-specific fields” tables
to complete these command fields.
Operation
Command
Integration ID (example)
#OUTPUT, 1, Action Number, Parameters
100% 75% 50% 25% 0%
Lift
Tilt
Commentaires sur ces manuels