Installation and Setup
40
Instruction Manual – DXLink Fiber™ Transmitters and Receivers, Duplex
Scenarios / DIP Switch Settings Table
The table below contains the most common scenarios for setting up Transmitters and Receivers with an
Enova DGX 8/16/32/64.
Find the scenario in the table that you want to use and then set the DIP switches accordingly. A detailed
explanation of functions for each toggle is provided on the previous page.
Important: Be sure that Toggles #2 and #4 are set to OFF.
Tip: Each toggle’s ON position is toward the connectors on the rear of the DXLink Fiber units (see page 38).
* Connect the ICS LAN 10/100 port of the DXLink Fiber unit to the network device (e.g., laptop, IP controlled projector,
AMX ICSLan EXB Device).
Mounting Options for DXLink Fiber Units (Rack Trays and Mounting Brackets)
The DXLink Fiber Transmitters and Receivers, Duplex are classified as V Style modules, which have optional
V Style mounting hardware. These versatile mounting options include rack trays and mounting brackets for desktops,
under desks, on walls, and on poles. For details on V Style Mounting Kit options, see www.amx.com.
Important: When mounting under a surface, the DXLink Fiber unit should be mounted upright and lowered in
the slots to provide an airflow gap between the surface and the vent holes. If not using V Style brackets, be
sure to leave a gap between the top of the unit and the surface for heat to escape.
Common Scenarios and Their DIP Switch Toggle Settings
Switcher Setup – TX/RX with Enova DGX Switcher #1 #2 #3 #4
AV signals only OFF OFF OFF OFF
AV with Ethernet pass through to networked device* ON OFF OFF OFF
AV with NetLinx control of TX/RX unit and serial/IR ports OFF OFF ON OFF
AV with NetLinx control of TX/RX unit and serial/IR ports,
plus Ethernet pass through to networked device*
ON OFF ON OFF
Caution: To prevent overheating, avoid placing high heat producing equipment directly above or below the
units. We recommend allowing plenty of clearance above the vent holes on top of the units. Do not place
anything directly on top of the units that would restrict airflow through the vent holes on top.
FIG. 13 V Style mounting hardware
V Style Single Module
Surface Mount Brackets
V Style Module Tray
V Style Single Module Pole Mount
Do not mount upside down
Leave minimum gap of 3/8 in (9 mm)