System Status Page
67
RMS Administrator’s Guide
History - Launches the Device Parameter History Page section on page 68.
Modify - Launches the Modify Parameter Page section on page 69.
Delete - Deletes the parameter.
See Also:
Configure Notification Template Page section on page 172 - modify notification
templates to fulfill your own needs.
Parameter Settings (Cont.)
Status Type The status represents the type of problem a faulted condition
represents. Status Types include:
Control System Error
Equipment Usage
Help Request
Maintenance
Modified Appointment
•Network
New Appointment
New NetLinx System
Not Assigned
Room Communication Error
Security
Server Status
System Communication Error
Example: When "Lamp Hours" changes from an un-faulted
(not greater than 1000) to a faulted (greater than 1000), this
change represents a "Maintenance Request" status that
requires an AV technician to repair the equipment. If the
"Device Online" parameter changes from "Online" to "Offline",
this change could represent a "Security" or "Control System
Error" status. The RMS application will route the status type to
the appropriate personnel as determined by the Notification
Configuration settings.
Alert Template The notification template to use when the parameter's value is
outside the normal operating range.
Advise when parameter
returns to normal range
The RMS application sends a notification for a parameter when
it returns to its normal operating range.
Advise Template The notification template to use when the parameter's value
returns to the normal operating range.