Programming the NXB-CCG (for Clear Connect Dimmers and Switches)
15
RPM Device Configuration Guide - NXB-CCG NetLinx Clear Connect Gateway
Configuring Buttons 1-6: Adding Dimmer Functions
To configure the Lighting Control Buttons 1-6 on the touch panel (see FIG. 42 on page 13) to match RPM Lighting
Scenes 1-6:
1. In the Program page, click on Button 1 (under CCT Processor in the Devices window) to open the Button 1 Details
page (FIG. 45).
2. In the Button 1 Details page, click Add Device to open the Add Devices To Button popup (FIG. 46):
3. Select Dimmer to add a dim level setting to Button 1.
4. Click Add to add the Dimmer to Button 1. This action closes the popup and adds the Dimmer Programming table
to the Button 1 Details page (FIG. 47):
The Dimmer Programming table consists of four columns:
You can add both a Dimmer and a Switch to a button. In this case, both functions will
be activated when that button is pressed on the touch panel. For example, Button 1
can be configured to place the dimmer at 20% as well as turn the switch to Off.
FIG. 45 NXB-CCG WebConsole - CCT Processor: Button 1 Details page
FIG. 46 Add Devices To Button popup
FIG. 47 Button Details page - Dimmer Programming table