77
Ring Detect: Activates the specified channel when the phone rings. The channel is restored when
the phone stops ringing.
House Phone Off Hook: Activates the specified channel when a house phone is off hook. The channel is
restored when the phone is hung up.
Communicator Fail: Activates the specified channel when the panel in unable to communicate with a
central station receiver. The channel is restored after the next valid transmission.
Trigger Options: Each trigger can send an on/off command during activation or restore. The trigger
descriptions (above) specify activation and restore conditions. Enter the total of the
appropriate options in the option location for each used trigger.
X-10 Options:
X-10 Transmissions: Some installations are noisy and have difficulty with X-10 transmissions. This option
allows transmissions to be made multiple times to ensure reception.
Delay X-10 transmission: Delay between multiple X-10 transmissions.
Echo Mode: This is a helpful feature for ensuring X-10 operation. Enabling this option will cause
the panel to speak the 3 digit unit assignments for all received X-10 transmissions
followed by the unit command. When transmissions made by the panel is included,
the system only speaks if it "hears" its own transmissions on the power line. This
feature helps determine when noise is causing transmissions to be lost.
50 Hz: Allows X-10 operation in foreign countries that use 50Hz power.
Output Control Assignment:
Channel: "Button" style devices can be used to operate control channels. This location
determines which Control Channel should be activated. Legal values are 1-16.
Channel On / Off/ Toggle: When an Output Channel is activated it can be used to always turn a channel on,
always turn a channel off, or toggle the control channel each time the "button device"
is activated.
Suppress speech: The panel will confirm all control channel activations in full speech each time a
"button" activation occurs. This option eliminates the confirmation speech.
Control Channel Locations:
On units: Amount of time when "automatic off" is used.
CHU / Chain: The "Activate Chain Channel" option in remote control channel options 3 determines
if the value in this location is used as an X-10 unit assignment or a chain channel
assignment.
X-10 unit assignment: Legal values 000 - 255 (000) disabled.
Chain channel assignment: Legal values are 000 - 008 (000) disabled.
Aux output number: Determines the auxiliary output that is controlled by the remote control channel.
Legal values:
001 - 007: Low current output pins
008: System relay
009 - 064: EXP8 assignments
000: Disabled