MXD-430 4.3” X Series Wall/Flush Mount Touch Panel
47
MXD/T-1000, MXD/T-700 and MXD-430 Modero X Series® Touch Panels
Installing the MXD-430 into a Wall
The MXD-430 comes with a clear plastic backbox (designed to attach the panel to most standard wall materials. This
backbox has two locking tabs (one on each side) to help lock the backbox to the wall.
These locking tabs are only extended AFTER the backbox is inserted into the wall. (FIG. 42).
Installing the Backbox
1.
Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.
2. For best results, use the MXD-430 Installation Template (68-5968-05) to ensure proper placement (FIG. 43).
The template is marked on one side with directions for both landscape and portrait installations to ensure that the
touch panel and Backbox are properly aligned.
FIG. 42 Oblique rear view of MXD-430 Backbox installation
MXD-430
(front)
Backbox
Backbox knockout
Locking tab
Locking tab
When installing the backbox, make sure that the assembly is in the correct position
and in the correct place. Once the locking tabs are extended and locked into place,
removing the backbox may be difficult without having access to the back of the wall
or causing damage to the wall.
In order to ensure a stable installation of the MXD-430, the thickness of the wall
material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches
(2.22cm). The mounting surface should also be smooth and flat.
FIG. 43 MXD-430 Installation Template
2 3/4"
4 1/4"
(10.80 cm)
(6.99 cm)