A - 26 Parameters, Variables and Commands Ver. 0002
KV32 (F1109) I2tDrive
KV36 F (F1111) I2tMotor
Function: Variables being used internally by the system. They measure the levels of the internal
load of the i
2
t calculation at the Drive and at the motor as "the percentage used of the
maximum.
Version: Operative from version 03.01 on. Renewed in version 04.01
KV40 (F1115) ExtBallastOverload
Function: It shows the percentage of load on the External Ballast resistor in a Compact Drive.
This is useful for the i
2
t protection of that resistor. A value over 100% in this variable
will trigger error 301.
Version: Operative from version 03.07 on.