Installation ManualEnvironment AccessoriesHPX-1600Retractable Connection Portand HPX ModulesLast Revised:4/27/2012
HPX-1600 Hydraport6 HPX-1600 Retractable Connection Port
Installing the HPX-16007HPX-1600 Retractable Connection Port Installing the HPX-1600ATTENTION READ THIS FIRST!A typical installation will include seve
Installing the HPX-16008 HPX-1600 Retractable Connection PortInstallation Location NotesThe Hydraport system requires a mounting surface from 19mm (
Installing the HPX-16009HPX-1600 Retractable Connection Port Note that due to the guide bushing and router bit, the final cutout will be smaller tha
Installing the HPX-160010 HPX-1600 Retractable Connection PortStep 3 - Prepare the TerminationsSome modules that are included in the final system requ
Installing the HPX-160011HPX-1600 Retractable Connection Port Note the direction of the screw bosses, as indicated in FIG. 8: For mounting surfaces le
Installing the HPX-160012 HPX-1600 Retractable Connection PortStep 4 - Insert the Modules1. Latch the system in the closed (down) position.2. Place th
Installing the HPX-160013HPX-1600 Retractable Connection Port 5. Route the cables from each module out the bottom (currently facing up) of the base as
Installing the HPX-160014 HPX-1600 Retractable Connection Port8. The included circuit breaker modules should also be connected to the Power Inlet asse
Installing the HPX-160015HPX-1600 Retractable Connection Port Step 5 - Install the Bottom CoverOnce all of the desired modules are installed, complete
AMX Limited Warranty and DisclaimerThis Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Part
Installing the HPX-160016 HPX-1600 Retractable Connection Port2. Ensure the Power Inlet Assembly Chassis Ground Lug is secured tightly to the HPX-1600
Installing the HPX-160017HPX-1600 Retractable Connection Port 4. Secure the bottom cover to the aluminum frame using the four provided screws. 5. Secu
Installing the HPX-160018 HPX-1600 Retractable Connection PortStep 6 - Install the Lift Spring AssembliesATTENTION: If modules have been installed in
Installing the HPX-160019HPX-1600 Retractable Connection Port 6. Repeat for the second lift spring assembly7. Slide the mounting sleeve towards the to
Installing the HPX-160020 HPX-1600 Retractable Connection PortStep 7 - Install the System Into the Mounting SurfaceTurn the system over and install th
Installing the HPX-160021HPX-1600 Retractable Connection Port Step 8 - Install the Retaining Ring1. Insert the four #6-32 x 1 3/8 retaining screws int
Installing the HPX-160022 HPX-1600 Retractable Connection PortFIG. 20 HPX-1600 Installed in mounting surfaceTop ViewBottom View
Installing the HPX-160023HPX-1600 Retractable Connection Port Step 9 - Install Power Cord (If Required)If AC power modules are to be used in Internati
Installing the HPX-160024 HPX-1600 Retractable Connection PortStep 10 - Install Shields1. Secure the two shields to each other using the 8 supplied sc
Installing the HPX-160025HPX-1600 Retractable Connection Port Step 11 - Secure CablesTerminate the backside connections as required for each cable exi
Table of ContentsiHPX-1600 Retractable Connection Port Table of ContentsHPX-1600 Hydraport ...
Installing the HPX-160026 HPX-1600 Retractable Connection Port
HPX-P200-xx Power Outlet Module27HPX-1600 Retractable Connection Port HPX-P200-xx Power Outlet ModuleOverviewThe HPX-P200-xx Hydraport Power Outlet Mo
HPX-P200-xx Power Outlet Module28 HPX-1600 Retractable Connection PortInstalling the HPX-P200-XX Power Outlet ModuleDisconnect the IEC C-14 Power Inle
HPX-P200-xx Power Outlet Module29HPX-1600 Retractable Connection Port Step 1 - Connect the HPX-P200-xx to the HPX-1600 Power Inlet AssemblyPlug the 3-
HPX-P200-xx Power Outlet Module30 HPX-1600 Retractable Connection PortStep 3 - Install the 10 Amp Circuit Breaker (Included with HPX-PAK-XX Accessory
HPX-PA-HVI High Voltage Isolator31HPX-1600 Retractable Connection Port HPX-PA-HVI High Voltage IsolatorOverviewThe HPX-PA-HVI High Voltage Isolator (F
HPX-PA-HVI High Voltage Isolator32 HPX-1600 Retractable Connection PortStep 1 - Install Low-Voltage Secondary Circuit ModulesInstall all low-voltage,
HPX-PA-HVI High Voltage Isolator33HPX-1600 Retractable Connection Port Step 4 - Mark and Trim High Voltage Isolator1.Position the High Voltage Isolato
4/12 ©2012 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without no
ii HPX-1600 Retractable Connection PortTable of Contents
HPX-1600 Hydraport1HPX-1600 Retractable Connection Port HPX-1600 HydraportOverviewThe HPC-1600 HydraPort Retractable Connection Port (FG550-cc) is the
HPX-1600 Hydraport2 HPX-1600 Retractable Connection PortProduct Specifications HPX-1600 SpecificationsDimensions (HWD):Max above mounting surface: 9
HPX-1600 Hydraport3HPX-1600 Retractable Connection Port HPX-1600 Specifications (Cont.)Compatibility (Cont.): • HPX-B050, Hydraport Blank Panel - 1/2
HPX-1600 Hydraport4 HPX-1600 Retractable Connection PortHPX-1600 Exploded ViewFIG. 2 provides an exploded view of the HPX-1600 Hydraport System, with
HPX-1600 Hydraport5HPX-1600 Retractable Connection Port FIG. 2 HPX-1600 Exploded ViewShield and (8)Mounting ScrewsShield and (8)Mounting ScrewsPower