AMX Sensors and Receivers IR Guide de dépannage Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 7
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
Application Advisory
AA-3(IR TS)
2.
Verify Emitter. (283M or 286M Blink
Style ONLY)
Remove the power supply from the
connecting block and all Emitters from
the output. Place a jumper wire on the
connecting block between IR and +12v.
Reconnect the Power Supply and one
emitter. The Emitter should Light bright
and solid. Repeat for all emitters.
3.
Verify Emitter. (282M or 284M NON
Blink Style)
Use a diode tester to verify proper
Emitter operation. Remove Emitter from
Connecting Block. Place the Positive
Lead of the tester on the TIP of the
Mono Mini Plug and the Negative Lead
on the Shield of the Mono Mini Plug.
Meter should read a voltage. When the
leads are reversed (Positive lead on
Shield and Negative lead on TIP) you
should not get any voltage reading at all.
4.
Verify IR Receiver.
Remove the power supply from the
connecting block and all Emitters from
the output. Place a jumper wire on the
connecting block between IR Signal and
GND. Reconnect the Power Supply.
With a known good hand-held remote,
shoot a constant IR Command at the
receiver and verify the TB LED on the
Receiver lights.