Installation and Wiring
16
ViewStat Color Communicating Thermostat
Installing the Indoor Flush Mount Sensor
FIG. 13 displays the two pieces of the indoor flush mount sensor. The two pieces are the sensor body
with the connected wire and the threaded outer case of the sensor.
FIG. 13 Indoor Flush Mount Sensor
Follow these steps to install the indoor flush mount sensor:
1. Drill a ½" hole into the drywall where you want to install the sensor.
2. Fish the cable that connects to the sensor from behind the drywall and out through the ½" hole so
that 6" - 12" of the cable hangs through the hole.
3. Feed the sensor wire through the center of the threaded outer case of the sensor and connect it to the
cable that is hanging through the hole in the wall as shown in FIG. 14.
FIG. 14 Sensor wire connected to cable