Quick Start Guide
NX-4200 NetLinx Integrated Controller
Overview
This guide pertains to the NX-4200 NetLinx Integrated Controller
(FG2106-04). The purpose of this document is to illustrate how to set up
the device in its simplest configuration. Additional Documentation for this
device is available at www.amx.com:
Refer to the NX-x200 Series Hardware Reference Manual for
additional details on installing, upgrading, and wiring the NX-4200.
Refer to the NX Series NetLinx Integrated Controllers WebConsole &
Programming Guide for detailed configuration instructions.
What’s in the Box?
The following items are included with the NX-4200:
1 2-pin 3.5 mm mini-Phoenix (female) PWR connector
1 4-pin 3.5 mm mini-Phoenix (female) AxLink connector
2 6-pin 3.5 mm mini-Phoenix female I/O connectors
2 8-pin 3.5 mm mini-Phoenix female Relay connectors
2 10-pin 3.5mm mini-Phoenix female RS232/422/485 connectors
6 5-pin 3.5mm mini-Phoenix female RS232 connectors
2 CC-NIRC, IR Emitters (FG10-000-11)
2 removable rack ears
Power Supply
The suggested power supply for the NX-4200 is a 13.5 VDC 6.6 A output,
suitable for 50° C.
Environmental Requirements
The environmental requirements for the NX-4200 are as follows:
Operating Temperature: 32° F (0° C) to 104° F (40° C)
Storage Temperature: 4° F (-15° C) to 140° F (60° C)
Operating Humidity: 5% to 85% RH
Connecting to Your Controller
Note: Ensure the PC you are using to connect to the controller has the
latest version of NetLinx Studio 4.0 installed on it.
Once the controller is powered on, you can connect to it through its IP address.
Note: NX-Series controllers fully support IPv6 network addressing. If the
LAN port is connected to an IPv6 capable network it will self select an
appropriate IPv6 address based on the discovered address parameters of
the network to which it’s attached.
Connecting to the NX-4200 over Ethernet
The NX-4200 is configured for DHCP addressing by default. The controller
uses link local addressing as a backup in case the DHCP server is
inaccessible. See the
Changing the IP Address section for information on
setting a static IP address. Verify there is an active LAN connection on the
controller’s LAN port before beginning this procedure.
1. Using category cable, connect the LAN port on the rear panel of the
controller to your external network.
FIG. 2
displays the location of the LAN port on the rear panel.
FIG. 1 NX-4200 rear panel
2. In NetLinx Studio, select Settings > Workspace Communications
Settings to open the Workspace Communication Settings dialog.
3. Click System Settings to open the Communication Settings dialog, and
select the Network tab.
4. Click Listen for Masters to open the Listen For Masters dialog, and click
Start Listening to begin listening for “blink” (UDP) messages from NetLinx
Masters on the same subnet. As Masters are discovered, they are added
to the List of Active NetLinx Master Controllers.
5. When you see the IP Address for the target Master in the List of Active
NetLinx Master Controllers, click Stop Listening.
6. Select the IP Address of the target Master and click Select to Add. The
New TCP/IP Setting dialog appears, indicating the selected IP address. Fill
in the available fields as necessary. Click OK to save changes and return
to the Communication Settings dialog. The new Master’s IP address now
appears in the List of Addresses.
7. With the newly added Master selected, click Select. The window updates
to indicate that the newly added and selected Master is now the current
communication configuration.
8. Click OK on each open dialog to exit and return to the workspace.
9. Refresh the Online Tree (select Refresh System Online Tree from the
Online Tree context menu) to connect to the Master.
Connecting to the NX-4200 via USB
If you do not have a DHCP server or if the controller has an unknown static
IP address, you obtain the IP address of the controller via USB.
1. Using a standard Type-B to Type-A USB cable, connect the Program
Port on the front panel of the controller to your PC.
FIG. 2 displays the location of the Program Port.
FIG. 2 NX-4200 front panel
2. Select Settings > Workspace Communications Settings to open the
Workspace Communication Settings dialog.
3. Click System Settings to open the Communication Settings dialog.
4. Select the USB tab. The USB tab features a list of Masters connected
to your PC via USB. The IP address of the Master appears in the IPv4
Address column.
5. Highlight your Master and click Select to connect to it.
Retrieving the IP Address of the NX-4200
The NX-4200 is configured for DHCP addressing by default. The controller
uses link local addressing as a backup in case the DHCP server is
inaccessible. The IP address of the NX-4200 is accessible from the front
panel LCD display on the unit.
1. Press the Display Control button on the front panel. The LCD display
beside the button activates.
2. Press downward on the Display Control button to navigate through the
status parameters until you reach LAN IPv4 Address. This is your
controller’s IP address which you can use to access the WebConsole.
FIG. 3 Display Control button
Switching the IP Address from a Dynamic to Static
To toggle between static and dynamic IP addresses,
hold the ID pushbutton
on the front panel of the NX-4200 for 10 seconds. When complete, the controller
automatically reboots itself. After the controller is fully booted, use the
Workspace Communications Settings dialog in NetLinx Studio to create a new
connection to the controller. See the Default IP Addresses section for the list of
default IP addresses.
Note: Ensure the controller is fully booted when you press and hold the ID
pushbutton. Pressing and holding the ID pushbutton while the controller is
booting resets the unit to its factory defaults.
Connect category cable
to the LAN port
Connect Type-B USB cable
to the Program Port
Display Control button
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Quick Start Guide

Quick Start GuideNX-4200 NetLinx Integrated ControllerOverviewThis guide pertains to the NX-4200 NetLinx Integrated Controller (FG2106-04). The purpos

Page 2 - Hardware Information

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).6/14©2014 AMX. All rights reserved. AMX and the

Commentaires sur ces manuels

Pas de commentaire